TABLE OF CONTENTSDECLARATION ............................................................................................................................ iAPPROVAL: ................................................................................................................................. iiKEY DEFINITIONS; ................................................................................................................... vLIST OF ACRONYM: ....................................................
ABSTRACT A cross-sectional study was done on the Topic: Assessment of knowledge of Danger Signs among pregnant women attending ANC in KIU-TH). Pregnancy is a normal process that results in a series of both physiological and psychological changes in expectant mothers. However, normal pregnancy may be accompanied by some problems and complications which is potentially life-threatening to the mother and the fetus. Fraser et al (2003). Danger sign(s) is a term used to refer to a group of symptom...
Abstract The objective of this study is to evaluate the performance of the SPECT gamma camera at Alnilien Medical Diagnostic Centre of Khartoum This study was carried out in Nuclear Medicine Department in Alnelein Medical Diagnostic Centre (NMDC) and the results were compared with the international guidelines. The study evaluates the following parameters: energy resolution, uniformity, sensitivity and linearity All results that obtained from the study have been compared with the accepta...
Abstract Integrating Administrative and Engineering Sciences, It has profound effect in Enriching both for the good of mankind, As the value management Approach depends on the Organization of Scientific Steps in order to reach the point of balance between quality, cost and time ,Which invited engineers to exploit and apply this approach during the different phases of the project to achieve this balance in all aspects of technical and administrative project in general. And the Proportion of h...
ABSTRACT The purpose of the study was to evaluate the radioprotective effects of Gongronema latifolio (GL) leaf extract on a whole-body irradiated wistar albino rats. A prospective experimental and cross-sectional design was adopted for this study and it included a control group and experimental group. Part of the control group (normal control NC) was not irradiated neither was it administered with GL extract but the other part (experimental control EC) was only exposed to graded radiation ...
ABSTRACT The aim of this study was to characterize stroke lesions and normal brain tissue in computed tomography (CT) images of Nigerian patients using statistical texture descriptors, and to identify the class of texture descriptor that is most suitable for computer-aided diagnosis of stroke. Non-contrast CT images of 164 stroke patients were obtained in contiguous slices from the base of the skull to the vertex from two private radiodiagnostic centres. Initially, two experienced radiologis...
ABSTRACT The main aim of radiotherapy is to destroy cancerous tissues with ionizing radiation while the other normal parts of the body are saved or spared. Intracavitary brachytherapy is a procedure in which radioactive sources are placed in the body cavities close to or inside the target volume to deliver radiation at short distances. In this mode of treatment, high radiation dose can be delivered to the tumour volume with rapid dose fall-off into the surrounding normal tissues. In brachyt...
ABSTRACT In radiotherapy, accuracy and precision are key, and thus, a small deviation in dose delivered by a treatment machine can be detrimental to patients. For this reason, in any radiotherapy department, linacs that have been tuned to match each other dosimetrically require critical assessment and evaluation since patients may be moved between linacs without any adjustments to treatment plans. The main aim of this study was to assess and evaluate the photon beam dosimetric accuracy betwe...
ABSTRACT The aim of this study was in two to investigate; firstly, (i) location of radiosensitive organs in the interior of four (4) paediatric anthropomorphic phantoms, and, secondly, (ii) effectiveness of single and double bismuth thyroid shields, distance between shield and phantom surface, during paediatric multi-detector computed tomography (MDCT) using fixed tube current (FTC) and automatic exposure control (AEC) on dose reduction and image quality. Four (4) paediatric anthropomorphic p...